%PDF- %PDF-
Direktori : /usr/src/linux-headers-5.15.0-125-generic/include/linux/input/ |
Current File : //usr/src/linux-headers-5.15.0-125-generic/include/linux/input/adxl34x.h |
/* SPDX-License-Identifier: GPL-2.0-or-later */ /* * include/linux/input/adxl34x.h * * Digital Accelerometer characteristics are highly application specific * and may vary between boards and models. The platform_data for the * device's "struct device" holds this information. * * Copyright 2009 Analog Devices Inc. */ #ifndef __LINUX_INPUT_ADXL34X_H__ #define __LINUX_INPUT_ADXL34X_H__ #include <linux/input.h> struct adxl34x_platform_data { /* * X,Y,Z Axis Offset: * offer user offset adjustments in twoscompliment * form with a scale factor of 15.6 mg/LSB (i.e. 0x7F = +2 g) */ s8 x_axis_offset; s8 y_axis_offset; s8 z_axis_offset; /* * TAP_X/Y/Z Enable: Setting TAP_X, Y, or Z Enable enables X, * Y, or Z participation in Tap detection. A '0' excludes the * selected axis from participation in Tap detection. * Setting the SUPPRESS bit suppresses Double Tap detection if * acceleration greater than tap_threshold is present during the * tap_latency period, i.e. after the first tap but before the * opening of the second tap window. */ #define ADXL_SUPPRESS (1 << 3) #define ADXL_TAP_X_EN (1 << 2) #define ADXL_TAP_Y_EN (1 << 1) #define ADXL_TAP_Z_EN (1 << 0) u8 tap_axis_control; /* * tap_threshold: * holds the threshold value for tap detection/interrupts. * The data format is unsigned. The scale factor is 62.5 mg/LSB * (i.e. 0xFF = +16 g). A zero value may result in undesirable * behavior if Tap/Double Tap is enabled. */ u8 tap_threshold; /* * tap_duration: * is an unsigned time value representing the maximum * time that an event must be above the tap_threshold threshold * to qualify as a tap event. The scale factor is 625 us/LSB. A zero * value will prevent Tap/Double Tap functions from working. */ u8 tap_duration; /* * tap_latency: * is an unsigned time value representing the wait time * from the detection of a tap event to the opening of the time * window tap_window for a possible second tap event. The scale * factor is 1.25 ms/LSB. A zero value will disable the Double Tap * function. */ u8 tap_latency; /* * tap_window: * is an unsigned time value representing the amount * of time after the expiration of tap_latency during which a second * tap can begin. The scale factor is 1.25 ms/LSB. A zero value will * disable the Double Tap function. */ u8 tap_window; /* * act_axis_control: * X/Y/Z Enable: A '1' enables X, Y, or Z participation in activity * or inactivity detection. A '0' excludes the selected axis from * participation. If all of the axes are excluded, the function is * disabled. * AC/DC: A '0' = DC coupled operation and a '1' = AC coupled * operation. In DC coupled operation, the current acceleration is * compared with activity_threshold and inactivity_threshold directly * to determine whether activity or inactivity is detected. In AC * coupled operation for activity detection, the acceleration value * at the start of activity detection is taken as a reference value. * New samples of acceleration are then compared to this * reference value and if the magnitude of the difference exceeds * activity_threshold the device will trigger an activity interrupt. In * AC coupled operation for inactivity detection, a reference value * is used again for comparison and is updated whenever the * device exceeds the inactivity threshold. Once the reference * value is selected, the device compares the magnitude of the * difference between the reference value and the current * acceleration with inactivity_threshold. If the difference is below * inactivity_threshold for a total of inactivity_time, the device is * considered inactive and the inactivity interrupt is triggered. */ #define ADXL_ACT_ACDC (1 << 7) #define ADXL_ACT_X_EN (1 << 6) #define ADXL_ACT_Y_EN (1 << 5) #define ADXL_ACT_Z_EN (1 << 4) #define ADXL_INACT_ACDC (1 << 3) #define ADXL_INACT_X_EN (1 << 2) #define ADXL_INACT_Y_EN (1 << 1) #define ADXL_INACT_Z_EN (1 << 0) u8 act_axis_control; /* * activity_threshold: * holds the threshold value for activity detection. * The data format is unsigned. The scale factor is * 62.5 mg/LSB. A zero value may result in undesirable behavior if * Activity interrupt is enabled. */ u8 activity_threshold; /* * inactivity_threshold: * holds the threshold value for inactivity * detection. The data format is unsigned. The scale * factor is 62.5 mg/LSB. A zero value may result in undesirable * behavior if Inactivity interrupt is enabled. */ u8 inactivity_threshold; /* * inactivity_time: * is an unsigned time value representing the * amount of time that acceleration must be below the value in * inactivity_threshold for inactivity to be declared. The scale factor * is 1 second/LSB. Unlike the other interrupt functions, which * operate on unfiltered data, the inactivity function operates on the * filtered output data. At least one output sample must be * generated for the inactivity interrupt to be triggered. This will * result in the function appearing un-responsive if the * inactivity_time register is set with a value less than the time * constant of the Output Data Rate. A zero value will result in an * interrupt when the output data is below inactivity_threshold. */ u8 inactivity_time; /* * free_fall_threshold: * holds the threshold value for Free-Fall detection. * The data format is unsigned. The root-sum-square(RSS) value * of all axes is calculated and compared to the value in * free_fall_threshold to determine if a free fall event may be * occurring. The scale factor is 62.5 mg/LSB. A zero value may * result in undesirable behavior if Free-Fall interrupt is * enabled. Values between 300 and 600 mg (0x05 to 0x09) are * recommended. */ u8 free_fall_threshold; /* * free_fall_time: * is an unsigned time value representing the minimum * time that the RSS value of all axes must be less than * free_fall_threshold to generate a Free-Fall interrupt. The * scale factor is 5 ms/LSB. A zero value may result in * undesirable behavior if Free-Fall interrupt is enabled. * Values between 100 to 350 ms (0x14 to 0x46) are recommended. */ u8 free_fall_time; /* * data_rate: * Selects device bandwidth and output data rate. * RATE = 3200 Hz / (2^(15 - x)). Default value is 0x0A, or 100 Hz * Output Data Rate. An Output Data Rate should be selected that * is appropriate for the communication protocol and frequency * selected. Selecting too high of an Output Data Rate with a low * communication speed will result in samples being discarded. */ u8 data_rate; /* * data_range: * FULL_RES: When this bit is set with the device is * in Full-Resolution Mode, where the output resolution increases * with RANGE to maintain a 4 mg/LSB scale factor. When this * bit is cleared the device is in 10-bit Mode and RANGE determine the * maximum g-Range and scale factor. */ #define ADXL_FULL_RES (1 << 3) #define ADXL_RANGE_PM_2g 0 #define ADXL_RANGE_PM_4g 1 #define ADXL_RANGE_PM_8g 2 #define ADXL_RANGE_PM_16g 3 u8 data_range; /* * low_power_mode: * A '0' = Normal operation and a '1' = Reduced * power operation with somewhat higher noise. */ u8 low_power_mode; /* * power_mode: * LINK: A '1' with both the activity and inactivity functions * enabled will delay the start of the activity function until * inactivity is detected. Once activity is detected, inactivity * detection will begin and prevent the detection of activity. This * bit serially links the activity and inactivity functions. When '0' * the inactivity and activity functions are concurrent. Additional * information can be found in the ADXL34x datasheet's Application * section under Link Mode. * AUTO_SLEEP: A '1' sets the ADXL34x to switch to Sleep Mode * when inactivity (acceleration has been below inactivity_threshold * for at least inactivity_time) is detected and the LINK bit is set. * A '0' disables automatic switching to Sleep Mode. See the * Sleep Bit section of the ADXL34x datasheet for more information. */ #define ADXL_LINK (1 << 5) #define ADXL_AUTO_SLEEP (1 << 4) u8 power_mode; /* * fifo_mode: * BYPASS The FIFO is bypassed * FIFO FIFO collects up to 32 values then stops collecting data * STREAM FIFO holds the last 32 data values. Once full, the FIFO's * oldest data is lost as it is replaced with newer data * * DEFAULT should be ADXL_FIFO_STREAM */ #define ADXL_FIFO_BYPASS 0 #define ADXL_FIFO_FIFO 1 #define ADXL_FIFO_STREAM 2 u8 fifo_mode; /* * watermark: * The Watermark feature can be used to reduce the interrupt load * of the system. The FIFO fills up to the value stored in watermark * [1..32] and then generates an interrupt. * A '0' disables the watermark feature. */ u8 watermark; /* * When acceleration measurements are received from the ADXL34x * events are sent to the event subsystem. The following settings * select the event type and event code for new x, y and z axis data * respectively. */ u32 ev_type; /* EV_ABS or EV_REL */ u32 ev_code_x; /* ABS_X,Y,Z or REL_X,Y,Z */ u32 ev_code_y; /* ABS_X,Y,Z or REL_X,Y,Z */ u32 ev_code_z; /* ABS_X,Y,Z or REL_X,Y,Z */ /* * A valid BTN or KEY Code; use tap_axis_control to disable * event reporting */ u32 ev_code_tap[3]; /* EV_KEY {X-Axis, Y-Axis, Z-Axis} */ /* * A valid BTN or KEY Code for Free-Fall or Activity enables * input event reporting. A '0' disables the Free-Fall or * Activity reporting. */ u32 ev_code_ff; /* EV_KEY */ u32 ev_code_act_inactivity; /* EV_KEY */ /* * Use ADXL34x INT2 pin instead of INT1 pin for interrupt output */ u8 use_int2; /* * ADXL346 only ORIENTATION SENSING feature * The orientation function of the ADXL346 reports both 2-D and * 3-D orientation concurrently. */ #define ADXL_EN_ORIENTATION_2D 1 #define ADXL_EN_ORIENTATION_3D 2 #define ADXL_EN_ORIENTATION_2D_3D 3 u8 orientation_enable; /* * The width of the deadzone region between two or more * orientation positions is determined by setting the Deadzone * value. The deadzone region size can be specified with a * resolution of 3.6deg. The deadzone angle represents the total * angle where the orientation is considered invalid. */ #define ADXL_DEADZONE_ANGLE_0p0 0 /* !!!0.0 [deg] */ #define ADXL_DEADZONE_ANGLE_3p6 1 /* 3.6 [deg] */ #define ADXL_DEADZONE_ANGLE_7p2 2 /* 7.2 [deg] */ #define ADXL_DEADZONE_ANGLE_10p8 3 /* 10.8 [deg] */ #define ADXL_DEADZONE_ANGLE_14p4 4 /* 14.4 [deg] */ #define ADXL_DEADZONE_ANGLE_18p0 5 /* 18.0 [deg] */ #define ADXL_DEADZONE_ANGLE_21p6 6 /* 21.6 [deg] */ #define ADXL_DEADZONE_ANGLE_25p2 7 /* 25.2 [deg] */ u8 deadzone_angle; /* * To eliminate most human motion such as walking or shaking, * a Divisor value should be selected to effectively limit the * orientation bandwidth. Set the depth of the filter used to * low-pass filter the measured acceleration for stable * orientation sensing */ #define ADXL_LP_FILTER_DIVISOR_2 0 #define ADXL_LP_FILTER_DIVISOR_4 1 #define ADXL_LP_FILTER_DIVISOR_8 2 #define ADXL_LP_FILTER_DIVISOR_16 3 #define ADXL_LP_FILTER_DIVISOR_32 4 #define ADXL_LP_FILTER_DIVISOR_64 5 #define ADXL_LP_FILTER_DIVISOR_128 6 #define ADXL_LP_FILTER_DIVISOR_256 7 u8 divisor_length; u32 ev_codes_orient_2d[4]; /* EV_KEY {+X, -X, +Y, -Y} */ u32 ev_codes_orient_3d[6]; /* EV_KEY {+Z, +Y, +X, -X, -Y, -Z} */ }; #endif